World Aquaculture Singapore 2026

June 2-5, 2026

Singapore

DRIVERS OF ELECTRICAL ENERGY CONSUMPTION IN RECIRCULATING AQUACULTURE SYSTEMS

Laura Klatt*, Sara M. Pinho, Christopher Shaw, Giovanni M. Turchini

School of Agriculture, Food and Ecosystem Sciences, Faculty of Science

The University of Melbourne, VIC 3010, Australia

laura.klatt@student.unimelb.edu.au



Recirculating Aquaculture Systems (RAS) are efficient farming systems, but energy intensive. Few studies distinguish energy consumption between individual components or identify the factors driving demand, limiting optimisation of system design and operation. This study aims to characterise baseline energy demand and variability across RAS components. It furthermore quantifies the operational and environmental drivers of electrical energy use by analysing relationships between component-level energy use and production parameters.

Eight identical experimental RAS were run at the Leibniz Institute of Freshwater Ecology and Inland Fisheries (IGB) in Berlin, Germany, from May to August 2026 with African catfish (Clarias gariepinus). Smart energy sensors monitored all energy-consuming components during the 13-week feeding trial. Electrical energy use was recorded at system and component levels, covering the circulation pump, trickling filter pump, blower, drumfilter, and temperature control. Feeding rates, biomass, water consumption, and environmental conditions were also recorded. Component-level data were analysed to quantify baseline energy demand and variability among compartments. Regression and correlation analyses identified operational and environmental drivers of energy use. Energy use efficiency was calculated based on the biomass produced and energy used.

The results show that drumfilter energy use increased over time with growing biomass and that energy use for temperature control was highly variable due to greenhouse environmental conditions. In total, temperature control dominated energy use at more than 60% of total consumption, followed by the blower (22.27%), trickling filter pump (10.58%), circulation pump (4.68%), and drumfilter (0.87%) (Figure 1). Preliminary correlation results indicate that electrical energy use efficiency in RAS strongly depends on external environmental conditions and fish growth performance.

By differentiating energy use among system compartments and identifying the main operational and environmental drivers, this study provides a basis for targeted optimisation of RAS design and operation, supporting more effective energy management strategies in aquatic animal farming.