BACKGROUND
Late or missed pathogen detection is one of the leading drivers of preventable economic losses in shrimp farming across Southeast Asia , through excess feed costs, mortality, and delayed treatment decisions. qPCR or quantitative PCR, while highly sensitive, requires laboratory infrastructure and 24-72 hours turnaround times incompatible with on-farm management. RAPID is a LAMP diagnostic platform developed by Forte Biotech that delivers results within one hour, requires no cold chain, and can be operated with minimal training at the pond side , giving farmers the information they need to act early and save money. This study evaluated its diagnostic performance against qPCR for two major shrimp pathogens: Enterocytozoon hepatopenaei (EHP) and Vibrio parahaemolyticus causing Acute hepatopancreatic necrosis disease (AHPND/EMS) .
METHODS
Validation was conducted across three independent cohorts: (1) Internal field validation in Vietnam – 383 paired shrimp samples across hatchery, nursery, and grow-out ponds tested under real on-farm conditions; (2) University of Arizona – controlled laboratory benchmarking (n=40 per target); and (3) BIOTEC/NSTDA– independent regional validation for EHP (n=40; 30 EHP-positive, 10 SPF-negative). All samples were run in parallel with reference qPCR. Limit of detection (LOD) was assessed internally and determined to be 15 copies per reaction under controlled laboratory conditions.
RESULTS
EHP performance was consistent across all three independent cohorts: 90.9% overall agreement under real on-farm field conditions (Vietnam, n=383), 97.5% in controlled laboratory benchmarking (University of Arizona, n=40), and 100% concordance across all 40 samples in the Thailand cohort (BIOTEC/NSTDA). For EMS/AHPND, RAPID demonstrated 93.3% sensitivity and 100% specificity (University of Arizona, n=40). Discordant results across all targets were concentrated at near-cutoff samples (Ct >35), consistent with inherent detection limits rather than systematic assay failure. Internal LOD testing confirmed detection at 15 copies per reaction. Time-to-result was within one hour, compared to 24-72 hours for laboratory qPCR.
CONCLUSION
RAPID demonstrates qPCR-comparable accuracy for EHP across three independent validation settings and for EMS/AHPND across one, spanning controlled laboratory and real on-farm conditions. The platform’s sub-hour turnaround, no cold chain requirement, and LOD of 15 copies per reaction make it a practical tool for routine pond-side deployment – enabling farmers to detect disease earlier, reduce unnecessary antibiotic use, and protect farm profitability. A prospective farm impact trial across 12 shrimp farms in Vietnam is being established for the second half of 2026 with support from Partnering for Green Growth and the Global Goals, designed to quantify downstream effects on antibiotic usage, feed efficiency, and farm productivity. Results will be reported at a subsequent World Aquaculture Society meeting.