World Aquaculture Singapore 2026

June 2-5, 2026

Singapore

DEVELOPMENT, VALIDATION, AND COMPARISON OF POINT-OF-CARE LAMP AND TMSD ASSAYS FOR RAPID DETECTION OF Haplosporidium nelsoni IN EASTERN OYSTERS Crassostrea virginica IN CANADA: A FRAMEWORK FOR INHIBITOR-RESILIENT AQUACULTURE DIAGNOSTICS

Author(s):
Tirosh Shapira *, Holly MacDonald , Lilian Figueiredo, Jordan Poley

Address and Email:
Onda, 20 Hope Street , Souris, PEI , C0A 2B0, Canada
Email: tshapira@onda.ca



Abstract:

Haplosporidium nelsoni, the causative agent of MSX disease, presents a persistent threat to Eastern oyster (Crassostrea virginica ) populations and aquaculture operations in  the USA and recently, in  Canada. Effective disease management requires rapid, sensitive, and field-deployable diagnostic tools capable of maintaining performance across diverse and inhibitor-rich sample matrices. This study uses MSX as a model system to develop, validate , and compare two point-of-care molecular detection platforms—loop-mediated isothermal amplification (LAMP) and toehold-mediated strand displacement (TMSD)—while establishing a broader framework for robust diagnostics in aquaculture settings.

 Primers and probe systems targeting conserved genomic regions of H. nelsoni were designed and optimized for rapid detection under minimal laboratory infrastructure. Assay performance was evaluated against standardized quantitative PCR (qPCR) diagnostics conducted in accordance with Fisheries and Oceans Canada (DFO) guidelines, providing a regulatory-relevant benchmark for sensitivity and specificity. Analytical validation included synthetic targets, infected oyster tissues, and complex environmental matrices representative of Canadian aquaculture conditions.

A central focus of this work was assay resilience to common inhibitors, including organic matter, salts, and host-derived compounds known to interfere with nucleic acid amplification. While both LAMP and TMSD platforms demonstrated reliable detection capabilities, TMSD assays showed superior performance in inhibitor-rich samples, maintaining sensitivity and signal fidelity where amplification-based methods exhibited reduced efficiency. Comparative analysis across platforms highlighted differences in limit of detection, time-to-result, and operational robustness under field-relevant conditions.

 Beyond MSX detection, this study establishes a transferable framework for the development of inhibitor-resilient, point-of-care diagnostics applicable to a wide range of aquaculture pathogens and species. By benchmarking against standardized qPCR methods and emphasizing performance in challenging sample matrices, these findings support the deployment of flexible, field-ready diagnostic tools to enhance disease surveillance, biosecurity, and management across the aquaculture industry.